At Quillfern Parcels. This is the system from chapter 7 of the Quillfern story, "Moving to the cloud": The office data room has one power feed. A cooling failure takes everything down for six hours on a Monday.
What the model simplifies
Illustrative figures: an instance is up 99.5% of the time, a zone 99.95%, a region 99.99%, the load balancer 99.99%; failures are independent and the surviving instances have enough capacity. Instance failures happen in zone A, as does a zone failure; the database primary is in zone A. Prices are made-up round numbers for comparison only, not any provider's. Every number on this page comes from one shared set of calculations, which the simulation questions use too, so a question can never disagree with what the simulator shows.
The drills, written out
Zone A goes down with the only database
- Healthy state. Two zones, two app instances in each, one database in zone A. Modelled availability is 99.430%.
- Trigger. A cooling failure takes zone A offline.
- What is affected. Zone B's app instances are healthy, but every booking needs the database, which was in zone A.
- Symptoms. The booking site returns errors for every page that reads or writes data. The load balancer's health checks still pass in zone B, because the app is up.
- Metrics. Error rate near 100%; database connection timeouts on every instance; recovery time: until the failed part comes back.
- Logs. The app logs show the database is unreachable.
ERROR could not connect to server: Connection timed out
Is the server running on host "orders-db" and accepting TCP/IP connections on port 5432?
- Reasoning. Two zones protect only what is in both. The single database was a single point of failure, so the second zone bought nothing in a zone outage.
- Mitigation. Run a synchronous standby in zone B with automatic failover. Now the same zone failure promotes the standby; recovery takes about 1–2 minutes of database failover.
- Recovery. Zone B serves all bookings with no data lost (RPO 0: the standby is synchronous). Cost rises to USD 685 a month from USD 495, which is the price of that protection.
- Prevention. List every dependency of a request and check it is in more than one zone; test it with a zone failure game day; make health checks include the database.
A whole region is lost
- Healthy state. Three zones and a synchronous standby: no single zone failure stops bookings. Modelled availability 99.977%.
- Trigger. A faulty change to the provider's regional network takes the whole region down for hours.
- What is affected. Everything: all zones of the region share the failure.
- Symptoms. The site does not answer at all; DNS still points at the region.
- Metrics. Every health check fails; time to recover: until the failed part comes back.
- Logs. Monitoring from outside the region shows connection timeouts; monitoring inside it is down too.
curl: (28) Connection timed out after 10001 milliseconds
- Reasoning. Zones protect against a building or power failure, not against a failure of the region itself. Only a copy in another region helps here.
- Mitigation. Keep an asynchronous replica in a second region with a small app tier. On a region failure, promote the replica and point DNS at the second region; that takes minutes to an hour.
- Recovery. Bookings resume from the second region; scans written in the last seconds before the failure may be missing (RPO seconds: the regional replica lags a little).
- Prevention. Write down the RTO and RPO the business needs, rehearse the regional failover, and keep DNS time-to-live short enough for that RTO.
Learn it properly